Burkert”s Type 8041 electromagnetic flow transmitter (pictured here) and Type 8045 insertion magmeter — each incorporating a stainless steel finger and fitting — meet high-temperature/high-pressure requirements for flow applications. The Type 8041 is an all-in-one device designed to operate as a transmitter and/or an on/off control unit with a -4 F to 302 F medium temperature range and 232 PSI maximum fluid pressure capability. The unit accommodates clean or contaminated liquids with a conductivity > 20 µS/cm. Compatible with pipe diameters from 1/2″ to 16 inches, the Type 8041 offers a measuring range of 0.33 FPS to 33 FPS. A bargraph provides flowrate visualization. Accuracy (for a measured value of 3.3 FPS to 33 FPS/-4 F to 266 F) is +/- 2 percent of measured value using Burkert’s Teach-In automatic calibration mode, +/- 4 percent of measured value using standard K-factor. Linearity is +/- 1 percent of measured value +/- 0.1 percent of FS, while repeatability is 0.25 percent of measured value.