Dear Pump Guy,

I stayed awake all night reading your articles on the Internet. I really liked your article on treating the symptoms of pump failure while ignoring the real illness. Your explanations of cavitation reach through many layers of understanding.

I have two questions:

  1. At what speed will cavitation begin in a pump?
  2. Is it advisable to have a variable-speed motor on a pump?

I hope to attend your seminar before I retire.

Prof. Amadu Bukari, Ph.D.

Hello Dr. Bukari,

Thanks for the kind words. I’ll answer your questions.

First, you asked: At what speed will the pump cavitate?
Each pump is different. It is impossible to look at a pump in a pipe system and say that cavitation will begin at some pre-determined speed.  

Cavitation and pump speed are generally not related. Cavitation is a function of the design of the suction side of the pump and impeller eye. Pump speed is determined by the driver or electric motor and the motor’s internal design.  

But strangely, there is a remote link between pump speed and cavitation—cavitation can start if and when the liquid’s energy (head and flow) leaves the pump on the discharge side faster than the liquid’s energy can enter the pump on the suction side.

The energy (head and flow of liquid) arriving into the pump is mostly a result of the design of the suction pipe, valves, elbows, fittings and process devices. This suction energy is mostly limited by the pipe diameter and pipe length between the suction tank or vessel and the pump. This energy is not tied to the pump’s speed.
As pump speed increases (with a variable speed motor, or pulleys, or a gearbox), the energy and liquid leaves the pump faster and faster as speed increases. There will be a point (a certain RPM) where the energy leaves the pump faster than the energy can enter into the pump. Cavitation will start.

Next, you asked: Is it advisable to have a variable-speed motor on your pump?

Sponsored Recommendations

Clean-in-Place (CIP) Solutions for Life Sciences Process Manufacturing

Learn how Emerson's measurement instrumentation can improve safety and reduce cross-contamination during CIP processes for life sciences process manufacturing.

Wireless Pressure Monitoring at Mining Flotation Cell

Eliminate operator rounds and improve flotation cell efficiency using reliable, wireless technology

Green hydrogen producer ensures quality of the network’s gas blend using a gas chromatograph

Case Study: Revolutionizing Green Hydrogen Blending with Precise Monitoring.

Overcome Measurement Challenges in Life Sciences

See how Emerson's best-in-class measurement instrumentation can help you overcome your toughest life sciences manufacturing challenges.