GLOSSARY OF TERMS: Flow Measurement

Dec. 21, 2006

ACCURACY: The deviation from the absolute truth; this figure should include linearity, repeatability, and calibration uncertainty. ASYMMETRIC FLOW: When the flow across a path of a liquid does not

ACCURACY: The deviation from the absolute truth; this figure should include linearity, repeatability, and calibration uncertainty.

ASYMMETRIC FLOW: When the flow across a path of a liquid does not have a symmetrical profile. This causes erroneous readings with most flowmeter types.

BACK PRESSURE: Measure of pressure on downstream side of a flowmeter.

BERNOULLI: Daniel Bernoulli’s formula basically states that the energy possessed at any point in a pipe is the same regardless of cross section.

CALIBRATION: The checking of a meter’s performance against known standard.

CAVITATION: When the pressure in a system drops, part of the flowing liquid either turns to a vapor or releases gasses that were in solution causing meter damage or erroneous readings.

DENSITY: Ratio of mass to volume.

DOPPLER EFFECT: The apparent change in frequency of a moving body relative to a reference point.

ELECTROMAGNETIC: Flowmeter that uses the same principle as an electric generator in that a voltage is induced when a conductor is moved in a magnetic field. The fluid is the conductor, and the meter body provides the magnetic field and the electrodes.

INSERTION METER: A term used for a flowmeter that is inserted to measure a point velocity in a fluid stream, the result of which is often used to calculate the flow in the whole conduit.

K FACTOR: The number of output pulses per unit volume from a flowmeter.

MASS FLOW: True mass flow where the measurement is a direct reading of the mass of the fluid, not just the volume or velocity.

MASTER METER: Typically a highly accurate flowmeter used as a reference for calibration purposes.

NUTATING DISC: Type of positive-displacement meter that uses a disc with a slot-in that “wobbles” rather than rotates on a spherical bearing in a specially shaped chamber.

ORIFICE PLATE: Differential-pressure device consisting of a plate that restricts the flow causing a predictable pressure loss using Bernoulli”s equation and the principle of the conservation of energy. May be concentric, eccentric, or chord.

PITOT TUBE: Differential-pressure device that utilizes the conversion of kinetic energy into pressure energy. Ideal for point measurement.

RANGEABILITY: Also called turndown. The ratio between the minimum and maximum flowrate for the linear flow range.

SLUG FLOW: Term used to describe a condition were the liquid in a pipe is interspersed with pockets of vapor that do not intermingle but travel in “slugs."

VORTEX SHEDDING: When a bluff body is introduced into a fluid stream it causes eddies to be shed from alternate sides at a frequency that is directly proportional to the fluid velocity.

The terms and definitions for this issue’s Word Search come from a glossary of terms compiled by Titan Enterprises Ltd. (www.flowmeters.co.uk), a United Kingdom-based manufacturer of flowmetering solutions.

Sponsored Recommendations

Clean-in-Place (CIP) Solutions for Life Sciences Process Manufacturing

Learn how Emerson's measurement instrumentation can improve safety and reduce cross-contamination during CIP processes for life sciences process manufacturing.

Wireless Pressure Monitoring at Mining Flotation Cell

Eliminate operator rounds and improve flotation cell efficiency using reliable, wireless technology

Green hydrogen producer ensures quality of the network’s gas blend using a gas chromatograph

Case Study: Revolutionizing Green Hydrogen Blending with Precise Monitoring.

Overcome Measurement Challenges in Life Sciences

See how Emerson's best-in-class measurement instrumentation can help you overcome your toughest life sciences manufacturing challenges.