Banner Advertisement
 

Current Issue
 
 
Click to visit this Sponsor!
Click to visit this Sponsor!
Click to visit this Sponsor!
Click to visit this Sponsor!
Click to visit this Sponsor!
Click to visit this Sponsor!
Click to visit this Sponsor!
Click to visit this Sponsor!
Click to visit this Sponsor!
 
 
October 2006
 
  Quiz Corner: Pipe Schedule & Flow Velocity
What's the Impact on Flow Measurement?
 
   
 

David W. Spitzer, P.E.
Sometimes we understand the effect of a certain error, but we do not take the time to determine its magnitude. Such can be the case of making an error with regard to pipe schedule. Assume a six-inch ultrasonic flowmeter in liquid service is designed and calibrated for Schedule 40 pipe, but is instead installed on a Schedule 80 pipe. How much does the flow measurement change due to the measurement of a different velocity in the metering section?

A. Increases by approx. 10%

B. Increases by approx. 5%
C. No effect
D. Decreases by approx. 5%
E. Decreases by approx. 10%

Commentary
The inside diameter of six-inch Schedule 40 and Schedule 80 pipes are 6.065 and 5.761 inches respectively. Because the inside diameter of the Schedule 80 pipe is smaller, the same amount of liquid will travel at a higher velocity in the Schedule 80 pipe metering section than in the Schedule 40 pipe. Therefore, when the flowmeter measures the fluid velocity in the metering section, the flowmeter measurement in the Schedule 80 metering section will be higher. This effectively eliminates Answer C, Answer D, and Answer E. The issue then becomes quantifying how much higher the flowmeter will measure.

Applying the equation of continuity, it can be seen that the ratio of the velocity in the Schedule 80 metering section to the velocity in the Schedule 40 metering section is proportional to the area of the metering sections.


Q = A1 * v1 = A2 * v2

Q = A Schedule 40 * v Schedule 40 =
A Schedule 80 * v Schedule 80

(v Schedule 80 / v Schedule 40) =
(A Schedule 40 / A Schedule 80)

The area of the pipe is proportional to the square of the diameter,

A = ¼ π D2

so the ratio of the velocities is:
(v Schedule 80 / v Schedule 40) =
(D2Schedule 40 * / D2Schedule 80)
= (6.0652 / 5.7612)
= 1.108

Therefore, the velocity increases by almost 11 percent, so the best answer is Answer A.

Additional Complicating Factors
Some ultrasonic flowmeters compensate for the wall thickness of the pipe. The Schedule 80 metering section has a thicker wall, so the compensation would be different and affect the flow measurement.

David W. Spitzer, P.E., is a regular contributor to Flow Control. He has more than 25 years of experience in specifying, building, installing, startup, and troubleshooting process control instrumentation. Mr. Spitzer is currently a principal in Spitzer and Boyes LLC, offering engineering, product development, marketing, and distribution consulting for manufacturing and automation companies. He can be reached at or 845 623-1830.

www.spitzerandboyes.com
 
     
   

Get a FREE Subscription to Flow Control magazine | Subscribe to the Flow Control E-Newsletter

 
 

GVMG

(c) 2009 EBSCO Industries, Inc. All rights reserved.
Grand View Media Group is a subsidiary of EBSCO Industries, Inc.

Site Developed & Maintained by the Pinnex Group, LLC

Privacy Policy