Quiz Corner: Steam flow measurement with vortex shedding flowmeter

Oct. 7, 2019
In this example, steam flow measurement is relatively steady until a sudden electrical outage occurs and trips all of the boilers. The operators restart the boilers approximately 15 minutes later. How do you expect the steam flow measurement to react between the trip and the restart?

A vortex shedding flowmeter is used to measure steam flow leaving a boiler house. The flow measurement is relatively steady until a sudden electrical outage occurs and trips all of the boilers. The operators scramble and finally restart the boilers approximately 15 minutes later. How do you expect the steam flow measurement to react between the trip and the restart?  

A. Flow steadily drops

B. Flow rises for a few minutes and then drops

C. Flow drops for a few minutes and then rises

D. Flow steadily rises

Logic would suggest that the steam flow will drop steadily after the trip until the boilers restart. After all, how can the steam flow rise if there is no fire in the boiler? Implicit in this analysis is that the term "steam flow" refers to the mass flow of steam. However, the vortex shedding flowmeter measures the velocity of the steam — not mass flow as may be suggested by its display in pounds or metric tons per hour.  

Steam generation will steadily drop after the boilers trip, so the steam header pressure will drop as the steam in the piping system is consumed. The drop in header pressure causes a given mass of generated steam to be larger than the same mass would be at its normal operating pressure. The net result is that the volume of the steam generated is temporarily so large for a given mass that the flow measurement actually increases before peaking and then dropping off. Answer B is correct.  

Additional complicating factors

Implementing a flow computer to compensate for pressure would improve accuracy during operation and provide a better representation of steam flow following a trip. 

David W. Spitzer

David W. Spitzer is a principal at Spitzer and Boyes, LLC, which offers engineering, focused market research, writing/editing white papers, strategic marketing consulting, distribution consulting, seminars and expert witness services for manufacturing and automation companies. Spitzer has written more than 400 technical articles and 10 books about flow measurement, instrumentation and process control. He can be reached at 845-623-1830 or via spitzerandboyes.com.

Sponsored Recommendations

Learn About: Micro Motion™ 4700 Config I/O Coriolis Transmitter

An Advanced Transmitter that Expands Connectivity

Micro Motion 4700 Coriolis Configurable Inputs and Outputs Transmitter

The Micro Motion 4700 Coriolis Transmitter offers a compact C1D1 (Zone 1) housing. Bluetooth and Smart Meter Verification are available.

Keys to Improving Safety in Chemical Processes

Many facilities handledangerous processes and products on a daily basis. Keeping everything undercontrol demands well-trained people workingwith the best equipment.

Micro Motion™ G-Series Coriolis Flow and Density Meter

Micro Motion G-Series: market-leading compact design featuring advanced process diagnostic capability.